• SYRINGE PUMP HD-MS54

    21,999.00 incl. GST

    Key Feature

    • Model: MS 54
    • Type: Syringe Pump
    • Dimensions: 140 mm (W) x 220 mm (H) x 320 mm (D)
    • Weight: Approximately 2.5 kg (5.5 lbs)
    • Power Supply: 100-240 VAC, 50-60 Hz
    • Battery Life: Up to 8 hours (rechargeable battery)
    • Flow Rate: 0.1-120 ml./h (in 0.1 ml/h Increments)
    • Syringe Size: 10ml, 20ml., 30ml., and 60ml.
    • Pumping Mode: Continuous, Intermittent, and Bolus
    • Infusion Volume: 0.1-9999 ml. (in 0.1 mL. Increments)
    • Infusion Time: 0-999 minutes (in I-minute Increments)

    Machine Specifications

    • Maximum infusion pressure 150kPa
    • Occlusion Alarm: Detects occlusions in the infusion line and alerts the user
    • Air in Line Alarm: Detects air in the Infusion line and alerts the user
    • Low Battery Alarm: Alerts the user when the battery level is low
    • Display: Backlit LCD display showing Infusion parameters, alarms, and battery status.

    Machine Specifications

    • Maximum infusion pressure 150kPa
    • Occlusion Alarm: Detects occlusions in the infusion line and alerts the user
    • Air in Line Alarm: Detects air in the Infusion line and alerts the user
    • Low Battery Alarm: Alerts the user when the battery level is low
    • Display: Backlit LCD display showing Infusion parameters, alarms, and battery status.
  • SYRINGE PUMP HD-SP950

    21,999.00 incl. GST

    Performance

    • Specification for syringe: 10 ml/20ml/30ml/50 ml syringe met na tional standards
    • Injection rate:

    10 ml 0.1 ml/h-200 ml/h

    20 ml 0.1 ml/h-400 ml/h

    30 ml 0.1 ml/h-600 ml/h

    50 ml 0.1 ml/h-1200 ml/h

    • Bolus rate:

    10 ml 200 ml/h

    20 ml 400 ml/h

    30 ml 600 ml/h

    50ml 1200 ml/h

    • Accumulated volume: 0ml-9999 ml
    • Injection accuracy: ±3%
    • Pressure range of occlusion alarm:

    Low: 40 kPa (±16kPa)

    Middle: 70 kPa (±30 kPa)

    High: 100 kPa (±35 kPa)

    • KVO rate: 0.1 ml/h
    • Class: Class II, type BF applied part, internally powered equipment
    • Alarm: occlusion, syringe out, motor abnormity, pressure failure, enter KVO, battery exhaustion, no syringe installed, near completion, low battery and standby prompt.

    Maximal power consumption: 25 VA, at least 4-hour continuous oper ation at the injection rate of 5 ml/h after fully charged.

    • Power supply: AC 100-240V, 50/60Hz
    • Battery: lithium battery, 7.4 V, 5000 mAh
  • Syringe Pump SP02