SYRINGE PUMP HD-MS54
₹21,999.00 incl. GSTKey Feature
- Model: MS 54
- Type: Syringe Pump
- Dimensions: 140 mm (W) x 220 mm (H) x 320 mm (D)
- Weight: Approximately 2.5 kg (5.5 lbs)
- Power Supply: 100-240 VAC, 50-60 Hz
- Battery Life: Up to 8 hours (rechargeable battery)
- Flow Rate: 0.1-120 ml./h (in 0.1 ml/h Increments)
- Syringe Size: 10ml, 20ml., 30ml., and 60ml.
- Pumping Mode: Continuous, Intermittent, and Bolus
- Infusion Volume: 0.1-9999 ml. (in 0.1 mL. Increments)
- Infusion Time: 0-999 minutes (in I-minute Increments)
Machine Specifications
- Maximum infusion pressure 150kPa
- Occlusion Alarm: Detects occlusions in the infusion line and alerts the user
- Air in Line Alarm: Detects air in the Infusion line and alerts the user
- Low Battery Alarm: Alerts the user when the battery level is low
- Display: Backlit LCD display showing Infusion parameters, alarms, and battery status.
Machine Specifications
- Maximum infusion pressure 150kPa
- Occlusion Alarm: Detects occlusions in the infusion line and alerts the user
- Air in Line Alarm: Detects air in the Infusion line and alerts the user
- Low Battery Alarm: Alerts the user when the battery level is low
- Display: Backlit LCD display showing Infusion parameters, alarms, and battery status.
-
SYRINGE PUMP HD-SP950
₹21,999.00 incl. GSTPerformance
- Specification for syringe: 10 ml/20ml/30ml/50 ml syringe met na tional standards
- Injection rate:
10 ml 0.1 ml/h-200 ml/h
20 ml 0.1 ml/h-400 ml/h
30 ml 0.1 ml/h-600 ml/h
50 ml 0.1 ml/h-1200 ml/h
- Bolus rate:
10 ml 200 ml/h
20 ml 400 ml/h
30 ml 600 ml/h
50ml 1200 ml/h
- Accumulated volume: 0ml-9999 ml
- Injection accuracy: ±3%
- Pressure range of occlusion alarm:
Low: 40 kPa (±16kPa)
Middle: 70 kPa (±30 kPa)
High: 100 kPa (±35 kPa)
- KVO rate: 0.1 ml/h
- Class: Class II, type BF applied part, internally powered equipment
- Alarm: occlusion, syringe out, motor abnormity, pressure failure, enter KVO, battery exhaustion, no syringe installed, near completion, low battery and standby prompt.
Maximal power consumption: 25 VA, at least 4-hour continuous oper ation at the injection rate of 5 ml/h after fully charged.
- Power supply: AC 100-240V, 50/60Hz
- Battery: lithium battery, 7.4 V, 5000 mAh
-
Syringe Pump SP02
₹15,999.00 incl. GST- High-precision infusion system for controlled drug delivery
- Digital display for accurate monitoring
- Adjustable flow rate for customized medication administration
- Compact and portable design for versatile use
- Ideal for hospitals, ICUs, and emergency care