Patient Monitor HD-11V

21,999.00

Feature

  • 12.1 inch, 800*600/1024×768 dpi, color TFT display:
  • Suitable for OT and ICU:
  • Separated module: Main board+Parameter module(ECG, NIBP, SpO2);
  • Display brightness adjustable;
  • Real time S-T segment analysis, and ARR analysis;
  • SpO2 Pitch Tone Variation and Drug Dose Calculation;
  • Parameter waveform and characters color selectable
  • Multi-display: Standard, Large font, Trend Coexis, OxyCRG dynamic
  • Standby mode for power saving and suspend monitoring.
  • 7-lead ECG waveforms display in phase,
  • Capture dynamic waveforms and history waveforms review,
  • VGA output:
  • Built-in rechargeable lithium battery 4 hours, and battery volume checking, Efficient resistance to interference of defibrillator and HF knife;
  • SD card memory and USB data output:
  • TCP/IP networking platform enable abundant future upgrade& CMS;
  • Complete and flexible mounting solution for transportation and
  • In-patient monitoring.

SPECIFICATIONS:

ECG:

  • Lead mode: 5-lead(R,L,F,N,C)
  • Lead selection: I,II,III,avR, avl,avF,V
  • Waveform: 3 and 7 channel selectable
  • Gain selection: 0.5mm/mv,1mm/mv,2mm/mv
  • Sweep speed: 12.5mm/s;25mm/s;50mm/s

Heart rate range:

Adult: 15~300bpm;

Neonate/Pediatric:15-350bpm

  • Accuracy: +1bpm or +1%, whichecer is greater
  • Resolution: 1bpm
  • Filter: surgery mode:1~20Hz
  • monitor model: 0.5~40Hz
  • Diagnostic mode: 0.05~130Hz
  • Scaling signal: 1mv,+3%
  • Protection: withstand 4000VAC/50 voltage isolation against electrosurgical interference and defibrillation
  • Alarm range: 15~350bpm

SPO2

  • Measurement range: 0~100%
  • Resolution: 1%
  • Accuracy: +2%(70-100%);0-69% unspecified
  • Alarm range: 0~100%
  • Pluse Rate: range:20~300bpm
  • Resolution: 1bpm
  • Error: +1bpm or +2%, whichever is greater

RESP:

  • Method: Thoracic impedance
  • Measurement range: Adult:7~120rpm;
  • Neonate/Pediatric:
  • 7~150rpm
  • Apnea alarm: YES,10~40s
  • Resolution: 1rpm
  • Accuracy: +2rpm

TEMP:

  • Compatible probe: YSI or CYF
  • Measurement range: 5~50°C
  • Resolution: 0.1°C
  • Accuracy: +0.1°C
  • Refreshing time: about 1
  • Average measuring time: <10s

NIBP:

  • Method: Digital Automatic oscillometric
  • Operation mode: Manual/Automatic/continuous
  • Auto measurement time: Adjustable(1~480min)
  • Measurement Unit: mmHg/Kpa selectable
  • Measurement types: Systolic, Diastolic, Mean

Measurement tange:

  • Range of Systolic pressure:
  • Adult: 40-270mmHg
  • Pediatric: 40~220mmHg
  • Neonate: 40~135mmHg
  • Range of mean pressure:
  • Adult: 20~235mmHg
  • Pediatric: 20-165mmHg
  • Neonate: 20~110mmHg

Range of diastolic pressure:

  • Adult: 10~215mmHg
  • Pediatric: 10~150mmHg
  • Neonate:10~100mmHg

Over-pressure protection:

  • Double safety protection
  • Resolution: 1 mmHg
  • Alarm: Systolic.Diastolic, Mean
  • IBP (Optional)
  • IBP Waveform: 2-Channel
  • Max 8 channels
  • Measurement Range: -50-350mmHg
  • Resolution: 1mmHg:
  • Unit: mmHg, kPa

Accuracy:

  • Static:±1mmHg or 2%, whichever is greater
  • (exclusive of transducer)
  • Dynamc: ±4mmHg or 4%, whichever is greater
  • Sensitivity of transducer: 5 uV/V/mmHg, ±2%
  • Impedance of transducer:300-3000 Ohm

Transducer sites:

  • ART, PA, LAP, RAP,CVP, ICP,P1,P2
  • Selection of measurement range:
  • ART: 0~+350mmHg
  • PA:-10~+120mmHg
  • CVP/RAP/LAP/ICP:-10~+40mmHg
  • P1/P2:-50+360mmHg

EtCO2( Sidertream CO2, Optional)

  • Measurement range: 0~99mmHg
  • Accuracy: +2mmHg (0~40mmHg)
  • Sampling Range: 100ml/min
  • Sampling rate accuracy: 15%
  • Respiration rate: 0~120rmp
  • Respiration accuracy: +2rmp (0~70rmp)
  • +5rmp (>70rmp)
  • Respiration time: 240msec (10% to 90%)
  • Delay time: <25

EtCO2 (Mainstreaam CO2, Optional)

  • Method: Infrared Spectrum
  • Range: 0.0-10% (0~76%)
  • Resolution: 1mmHg (0.1%)
  • Accuracy: <5%(±4.0 mmHg)
  • Or 10% (of Readings)

Suntech(Suntech):

  • Technique: Oscillometric
  • Patient Applications: Adult Pediatric, Neonate
  • Systolic Range: 40-265mmHh
  • Diatolic Range: 20-200mmHh
  • MAP Range: 27-222mmHh
  • Pulse Range: 25-300BPM
  • Transducer Accuracy: ±3mHg up to full range
  • Operation Conditions:
  • 0°C to 50°C, 15% to 95% non-condensing RH
  • Storage Conditions:
  • -20°C to 65 °C, 15%to 95% non-condensing RH

Recorder (Optional)

  • Build-in, thermal array
  • Plethysmogram caveform: 2 channels
  • Record mode: manual, on alarm, time-defined
  • Recording width: 50mm
  • Printing speed: 50mm/s
  • Recording type: Frozen waveform record
  • NIBP recall record
  • Trend table record
  • Alarm record
  • Fixed-time record
Compare

Description

The Patient Monitor HD-11V is a versatile, high-performance device designed to monitor patient vital signs in real-time across various medical settings. Featuring an intuitive interface, the HD-11V tracks critical parameters like heart rate, blood pressure, SpO2, and respiratory rate. It offers a high-resolution display, customizable alarms, and advanced data storage capabilities. With built-in connectivity, the monitor integrates easily into hospital information systems for seamless data sharing. The HD-11V is ideal for use in intensive care units, emergency departments, and operating rooms, delivering reliable, continuous monitoring to enhance patient safety and care quality.

Reviews

There are no reviews yet.

Be the first to review “Patient Monitor HD-11V”

Your email address will not be published. Required fields are marked *