• Infusion Pump Beyond

    24,999.00 incl. GST
    • Precise Flow Control: Adjustable infusion rates ensure that fluids and medications are delivered at the exact rate for patient safety and treatment.
    • Multiple Syringe Compatibility: Supports various syringe sizes, providing flexibility for different treatments and medical procedures in diverse clinical environments.
    • Air Bubble Detection: Automatically identifies air bubbles, preventing them from entering the patient’s system and causing potential harm or complications.
    • Occlusion Detection: Detects blockages or resistance in the infusion line, ensuring smooth fluid delivery and preventing therapy interruptions or delays.
    • Compact and Portable: Lightweight and space-efficient, infusion pumps are easy to transport, making them ideal for bedside and mobile applications.
    • Battery Backup: Equipped with rechargeable batteries that allow continued operation during power outages, ensuring uninterrupted medication and fluid delivery.
    • Real-Time Monitoring: Continuously tracks infusion rates, volumes, and remaining medication, providing accurate data for healthcare providers to optimize treatment.
    • Audible & Visual Alarms: Multi-sensory alarms alert caregivers to any infusion issues, such as air bubbles, occlusions, or syringe malfunctions, prompting quick intervention.
    • User-Friendly Interface: Intuitive display and controls simplify pump operation, making it easier for healthcare professionals to adjust settings and monitor infusion status.
    • Enhanced Safety Features: Includes anti-bolus protection, syringe error detection, and other safety mechanisms to minimize risks associated with medication delivery.
    Rate 1ml/h ~ 1,200ml/h
    Flow Rate Accuracy Within ±5% (after correct calibration)
    Mechanical precision Within ±2%
    Purge Rate 100ml/h ~ 1,000ml/h (100 ml/h step)
    Infusion Volume 1ml ~ 9999ml
    Total Infusion Volume 0.1ml ~ 9999.9ml
    KVO rate 1ml/h ~ 5 ml/h (1ml/h step)
    Occlusion High: 800mmHg ±200mmHg (106.7kPa±26.7kPa
    Medium: 500mmHg ±100mmHg(66.7kPa±13.3kPa
    Low: 300mmHg ±100mmHg (40.7kPa±13.3kPa )
    Unique audible and visible alarm Human voice alarm for End of injection, occlusion, door open, bubbles in the tube, wrong setting, low battery, AC power pulled out etc.
    Power Source AC 100V ~ 240V, 50/60Hz; Internal rechargeable Li battery, capacity≥1,600mAh, 4 hours internal battery backup
    Bubble detector Ultrasonic wave detector; detection sensitivity ≥25μL
    Fuse F1AL/250V, 2 pc inside
    Power Consumption 18VA
    Operating Condition Ambient temperature: +5℃ ~ +40℃;
    Relative humidity: 20 ~ 90%
    Atmospheric pressure: 86.0kpa ~ 106.0kpa
    Transport & Storage Condition Ambient temperature:-30℃ ~ +55℃
    Relative humidity: ≤95%
    Equipment Classification Class II, internal power supply, Type CF
    IP Classification IPX4
    Dimension 140mm (L) ×157mm(W) ×220mm(H)
    Weight 1.8kg (net weight)
  • Multipara Patient Monitor Yk-8000c (with Adult Probe)

    27,999.00 incl. GST
    • High-resolution color display for real-time monitoring
    • Supports ECG, heart rate, SpO2, NIBP, and temperature measurements
    • User-friendly interface with intuitive controls
    • Built-in rechargeable battery for portability
    • Comes with an adult probe for accurate measurements
  • Patient Monitor HD-11V

    24,999.00 incl. GST

    Feature

    • 12.1 inch, 800*600/1024×768 dpi, color TFT display:
    • Suitable for OT and ICU:
    • Separated module: Main board+Parameter module(ECG, NIBP, SpO2);
    • Display brightness adjustable;
    • Real time S-T segment analysis, and ARR analysis;
    • SpO2 Pitch Tone Variation and Drug Dose Calculation;
    • Parameter waveform and characters color selectable
    • Multi-display: Standard, Large font, Trend Coexis, OxyCRG dynamic
    • Standby mode for power saving and suspend monitoring.
    • 7-lead ECG waveforms display in phase,
    • Capture dynamic waveforms and history waveforms review,
    • VGA output:
    • Built-in rechargeable lithium battery 4 hours, and battery volume checking, Efficient resistance to interference of defibrillator and HF knife;
    • SD card memory and USB data output:
    • TCP/IP networking platform enable abundant future upgrade& CMS;
    • Complete and flexible mounting solution for transportation and
    • In-patient monitoring.

    SPECIFICATIONS:

    ECG:

    • Lead mode: 5-lead(R,L,F,N,C)
    • Lead selection: I,II,III,avR, avl,avF,V
    • Waveform: 3 and 7 channel selectable
    • Gain selection: 0.5mm/mv,1mm/mv,2mm/mv
    • Sweep speed: 12.5mm/s;25mm/s;50mm/s

    Heart rate range:

    Adult: 15~300bpm;

    Neonate/Pediatric:15-350bpm

    • Accuracy: +1bpm or +1%, whichecer is greater
    • Resolution: 1bpm
    • Filter: surgery mode:1~20Hz
    • monitor model: 0.5~40Hz
    • Diagnostic mode: 0.05~130Hz
    • Scaling signal: 1mv,+3%
    • Protection: withstand 4000VAC/50 voltage isolation against electrosurgical interference and defibrillation
    • Alarm range: 15~350bpm

    SPO2

    • Measurement range: 0~100%
    • Resolution: 1%
    • Accuracy: +2%(70-100%);0-69% unspecified
    • Alarm range: 0~100%
    • Pluse Rate: range:20~300bpm
    • Resolution: 1bpm
    • Error: +1bpm or +2%, whichever is greater

    RESP:

    • Method: Thoracic impedance
    • Measurement range: Adult:7~120rpm;
    • Neonate/Pediatric:
    • 7~150rpm
    • Apnea alarm: YES,10~40s
    • Resolution: 1rpm
    • Accuracy: +2rpm

    TEMP:

    • Compatible probe: YSI or CYF
    • Measurement range: 5~50°C
    • Resolution: 0.1°C
    • Accuracy: +0.1°C
    • Refreshing time: about 1
    • Average measuring time: <10s

    NIBP:

    • Method: Digital Automatic oscillometric
    • Operation mode: Manual/Automatic/continuous
    • Auto measurement time: Adjustable(1~480min)
    • Measurement Unit: mmHg/Kpa selectable
    • Measurement types: Systolic, Diastolic, Mean

    Measurement tange:

    • Range of Systolic pressure:
    • Adult: 40-270mmHg
    • Pediatric: 40~220mmHg
    • Neonate: 40~135mmHg
    • Range of mean pressure:
    • Adult: 20~235mmHg
    • Pediatric: 20-165mmHg
    • Neonate: 20~110mmHg

    Range of diastolic pressure:

    • Adult: 10~215mmHg
    • Pediatric: 10~150mmHg
    • Neonate:10~100mmHg

    Over-pressure protection:

    • Double safety protection
    • Resolution: 1 mmHg
    • Alarm: Systolic.Diastolic, Mean
    • IBP (Optional)
    • IBP Waveform: 2-Channel
    • Max 8 channels
    • Measurement Range: -50-350mmHg
    • Resolution: 1mmHg:
    • Unit: mmHg, kPa

    Accuracy:

    • Static:±1mmHg or 2%, whichever is greater
    • (exclusive of transducer)
    • Dynamc: ±4mmHg or 4%, whichever is greater
    • Sensitivity of transducer: 5 uV/V/mmHg, ±2%
    • Impedance of transducer:300-3000 Ohm

    Transducer sites:

    • ART, PA, LAP, RAP,CVP, ICP,P1,P2
    • Selection of measurement range:
    • ART: 0~+350mmHg
    • PA:-10~+120mmHg
    • CVP/RAP/LAP/ICP:-10~+40mmHg
    • P1/P2:-50+360mmHg

    EtCO2( Sidertream CO2, Optional)

    • Measurement range: 0~99mmHg
    • Accuracy: +2mmHg (0~40mmHg)
    • Sampling Range: 100ml/min
    • Sampling rate accuracy: 15%
    • Respiration rate: 0~120rmp
    • Respiration accuracy: +2rmp (0~70rmp)
    • +5rmp (>70rmp)
    • Respiration time: 240msec (10% to 90%)
    • Delay time: <25

    EtCO2 (Mainstreaam CO2, Optional)

    • Method: Infrared Spectrum
    • Range: 0.0-10% (0~76%)
    • Resolution: 1mmHg (0.1%)
    • Accuracy: <5%(±4.0 mmHg)
    • Or 10% (of Readings)

    Suntech(Suntech):

    • Technique: Oscillometric
    • Patient Applications: Adult Pediatric, Neonate
    • Systolic Range: 40-265mmHh
    • Diatolic Range: 20-200mmHh
    • MAP Range: 27-222mmHh
    • Pulse Range: 25-300BPM
    • Transducer Accuracy: ±3mHg up to full range
    • Operation Conditions:
    • 0°C to 50°C, 15% to 95% non-condensing RH
    • Storage Conditions:
    • -20°C to 65 °C, 15%to 95% non-condensing RH

    Recorder (Optional)

    • Build-in, thermal array
    • Plethysmogram caveform: 2 channels
    • Record mode: manual, on alarm, time-defined
    • Recording width: 50mm
    • Printing speed: 50mm/s
    • Recording type: Frozen waveform record
    • NIBP recall record
    • Trend table record
    • Alarm record
    • Fixed-time record
  • Patient Monitor Machine 3 para CMS5100

    11,999.00 incl. GST

    Perfect for Hospital, Homecare, Ambulance Services, & Clinics | Color Display | Non-Invasive Design | Alarm System | Suitable for All Ages

    • 3 vital sign parameters: ECG, SpO2, and NIBP
    • Color display for easy data interpretation
    • Non-invasive design for patient comfort
    • Real-time alarm system for prompt medical response
    • Suitable for all ages in hospitals, homecare, ambulances, and clinics
  • SYRINGE PUMP HD-SP950

    21,999.00 incl. GST

    Performance

    • Specification for syringe: 10 ml/20ml/30ml/50 ml syringe met na tional standards
    • Injection rate:

    10 ml 0.1 ml/h-200 ml/h

    20 ml 0.1 ml/h-400 ml/h

    30 ml 0.1 ml/h-600 ml/h

    50 ml 0.1 ml/h-1200 ml/h

    • Bolus rate:

    10 ml 200 ml/h

    20 ml 400 ml/h

    30 ml 600 ml/h

    50ml 1200 ml/h

    • Accumulated volume: 0ml-9999 ml
    • Injection accuracy: ±3%
    • Pressure range of occlusion alarm:

    Low: 40 kPa (±16kPa)

    Middle: 70 kPa (±30 kPa)

    High: 100 kPa (±35 kPa)

    • KVO rate: 0.1 ml/h
    • Class: Class II, type BF applied part, internally powered equipment
    • Alarm: occlusion, syringe out, motor abnormity, pressure failure, enter KVO, battery exhaustion, no syringe installed, near completion, low battery and standby prompt.

    Maximal power consumption: 25 VA, at least 4-hour continuous oper ation at the injection rate of 5 ml/h after fully charged.

    • Power supply: AC 100-240V, 50/60Hz
    • Battery: lithium battery, 7.4 V, 5000 mAh